{"id":465,"date":"2025-07-04T09:55:44","date_gmt":"2025-07-04T01:55:44","guid":{"rendered":"https:\/\/www.bihec.com\/sterlitech-adhensive\/?p=465"},"modified":"2025-07-04T10:32:29","modified_gmt":"2025-07-04T02:32:29","slug":"sterlitech-%e8%bf%87%e6%bb%a4%e5%99%a8-ceramic-membrane-0-14-micron-47mm-5-pk-%e5%ba%94%e7%94%a8%e4%ba%8e%e7%ba%af%e5%8c%96%e7%bb%86%e8%83%9e%e3%80%81%e9%85%b5%e6%af%8d%e3%80%81%e8%9b%8b%e7%99%bd","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/sterlitech-adhensive\/sterlitech-%e8%bf%87%e6%bb%a4%e5%99%a8-ceramic-membrane-0-14-micron-47mm-5-pk-%e5%ba%94%e7%94%a8%e4%ba%8e%e7%ba%af%e5%8c%96%e7%bb%86%e8%83%9e%e3%80%81%e9%85%b5%e6%af%8d%e3%80%81%e8%9b%8b%e7%99%bd\/","title":{"rendered":"Sterlitech \u8fc7\u6ee4\u5668 47M014 Ceramic Membrane, 0.14 Micron, 47mm, 5\/Pk \u5e94\u7528\u4e8e\u7eaf\u5316\u7ec6\u80de\u3001\u9175\u6bcd\u3001\u86cb\u767d\u8d28\u3001\u7ec6\u83cc\u3001\u8840\u6e05\u3001\u8089\u6c64\u6216\u9176"},"content":{"rendered":"

\"\"<\/h4>\n

47M014<\/a> Ceramic<\/a> Membrane\u00a0 0.14 Micron, 47mm<\/a>, 5\/Pk
\n\u5e94\u7528\u4e8e
\u7eaf\u5316\u7ec6\u80de<\/a>\u3001\u9175\u6bcd<\/a>\u3001\u86cb\u767d\u8d28<\/a>\u3001\u7ec6\u83cc<\/a>\u3001\u8840\u6e05<\/a>\u3001\u8089\u6c64<\/a>\u6216\u9176<\/a>
\n<\/span><\/h4>\n

 <\/p>\n

General<\/h3>\n
\n\n\n\n\n\n\n
Sterilization<\/a><\/strong><\/td>\nEtO, Autoclave<\/td>\n<\/tr>\n
Thickness<\/strong><\/td>\n2.5 mm<\/td>\n<\/tr>\n
Max. Pressure<\/strong><\/td>\n4 bar (58 psi)<\/td>\n<\/tr>\n
Max. Operating Temp<\/strong><\/td>\n350 \u00b0C (662 \u00b0F)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

Performance by Pore Size<\/h3>\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
<\/th>\nDesignation<\/span>1<\/sup><\/th>\npH Range<\/th>\nActive Layer<\/th>\n<\/tr>\n<\/thead>\n
1 kDa<\/strong><\/td>\nFine UF<\/a><\/td>\n2-14<\/td>\nTiO<\/span>2<\/sub><\/td>\n<\/tr>\n
3 kDa<\/strong><\/td>\nFine UF<\/td>\n2-14<\/td>\nTiO<\/span>2<\/sub><\/td>\n<\/tr>\n
5 kDa<\/strong><\/td>\nFine UF<\/td>\n2-14<\/td>\nTiO<\/span>2<\/sub><\/td>\n<\/tr>\n
8 kDa<\/strong><\/td>\nFine UF<\/td>\n2-14<\/td>\nTiO<\/span>2<\/sub><\/td>\n<\/tr>\n
15 kDa<\/strong><\/td>\nUF<\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub><\/td>\n<\/tr>\n
50 kDa<\/strong><\/td>\nUF<\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub><\/td>\n<\/tr>\n
150 kDa<\/strong><\/td>\nUF<\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub><\/td>\n<\/tr>\n
300 kDa<\/strong><\/td>\nUF<\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub><\/td>\n<\/tr>\n
0.14 \u00b5m<\/strong><\/td>\nMF<\/a><\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub>-TiO<\/span>2<\/sub><\/td>\n<\/tr>\n
0.20 \u00b5m<\/strong><\/td>\nMF<\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub>-TiO<\/span>2<\/sub><\/td>\n<\/tr>\n
0.45 \u00b5m<\/strong><\/td>\nMF<\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub>-TiO<\/span>2<\/sub><\/td>\n<\/tr>\n
0.80 \u00b5m<\/strong><\/td>\nMF<\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub>-TiO<\/span>2<\/sub><\/td>\n<\/tr>\n
1.40 \u00b5m<\/strong><\/td>\nMF<\/td>\n0-14<\/td>\nZrO<\/span>2<\/sub>-TiO<\/span>2<\/sub><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n

*Notes:<\/span>
\n1<\/sup><\/strong>\u00a0Fine UF membranes are shipped dry, but must be stored wet after first use. Sterlitech recommends using a solution of 1% sodium metabilsulfite in ultrapure water and storing the wetted membranes in a zip-closure bag to prevent growth of microorganisms.<\/em><\/p>\n